SDR is the standard dimension ratio of a plastic pipe: its outside diameter divided by
its wall thickness.
SDR = outside diameter ÷ wall thickness
A DN110 pipe with a 6.6 mm wall is 110 ÷ 6.6 = 16.7, which is the class SDR 17. The ratio
is what matters rather than the two measurements on their own: a thin-walled small pipe and a
thin-walled large pipe behave the same way, so one number describes the proportions of the
whole family. That is why pipe is ordered as DN110 SDR 17 and not as two dimensions.
A low SDR is a thick wall for the diameter — a stronger pipe, rated for more pressure. A
high SDR is a thin wall — cheaper, lighter, and for gravity or low-pressure duty.
Each class carries a nominal pressure rating, PN, in bar. The rating below is for PE100,
which is what landfill gas and leachate wells are normally built from; the same class in PE80
carries a lower PN.
| Class | Rating | Typically used for |
|---|---|---|
| SDR 7.4 | PN 25 | High-pressure industrial lines and deep wells |
| SDR 9 | PN 20 | Gas distribution and high-pressure water |
| SDR 11 | PN 16 | Standard water and utility mains |
| SDR 17 | PN 10 | Large-diameter or lower-pressure water systems |
| SDR 21 | PN 8 | Low-pressure or gravity applications |
| SDR 26 | PN 6.3 | Low-pressure or gravity applications |
Landfill gas wells are usually SDR 17 or SDR 11 in DN110 or DN160.
On a well's record page, the Well profile card asks for the pipe in the order it is
specified:
The internal diameter — the bore the gas or leachate actually flows through — is worked
out from the outside diameter less both walls, and shown beside them. It is never stored: two
measurements and a ratio already say what it is, and a stored third value can only contradict
them.
Leave SDR empty and type the wall thickness yourself. That is how well dimensions were
recorded before the picker existed, and nothing about it has changed. The profile will still
tell you which class the two dimensions come out as.
The wall thickness above comes straight from the definition — diameter ÷ SDR. The wall a pipe
is actually sold with is that quotient rounded up to the next tenth of a millimetre in the
ISO 4427-2 table, so the two can differ slightly:
| Pipe | Diameter ÷ SDR | Nominal wall |
|---|---|---|
| DN110 SDR 17 | 6.5 mm | 6.6 mm |
| DN160 SDR 17 | 9.4 mm | 9.5 mm |
The calculated value is a starting point, not a lock: the field stays editable, so if you have
the pipe's datasheet or delivery note, type the nominal wall from it. The class is unaffected —
110/6.6 and 110/6.5 are both SDR 17.